{"product_id":"bard-lopez®-enteral-valve-for-nasogastric-tube-adult-50-cs","title":"0056000 - Bard LOPEZ® Enteral Valve for Nasogastric Tube, Adult, 50\/cs","description":"\u003ch3\u003eLOPEZ® Enteral Valve for Nasogastric Tube, Adult, 50\/cs\u003c\/h3\u003e\n\u003cp\u003ePlease note: All prices are for cases.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe LOPEZ® Enteral Valve (0056000) is a medical-grade three-way stopcock designed to maintain a closed enteral system during irrigation, medication administration, and gastric drainage. By utilizing this valve (0056000), healthcare providers can access nasogastric (NG) or other enteral tubes without the frequent disconnection of feeding lines or the use of manual plugs. The device (0056000) is engineered to reduce clinician exposure to potentially infectious gastric secretions and bloodborne pathogens by providing a secure, leak-resistant port for syringe access.\u003c\/p\u003e\n\u003cp data-path-to-node=\"3\"\u003eConstructed from durable polycarbonate and polyethylene, the LOPEZ® Valve (0056000) features a universal adapter that allows for a secure connection to most standard feeding sets and enteral tubes. This adult-sized valve (0056000) is specifically designed to facilitate continuous gastric lavage and high-volume sumping when used in conjunction with dual-lumen stomach tubes. The integrated stopcock allows for easy switching between the suction\/feeding source and the medication port, streamlining routine enteral care while maintaining a hygienic clinical environment.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eThree-Way Stopcock Design:\u003c\/b\u003e Enables seamless transitions between feeding, suction, and medication administration without opening the system to air.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eClosed-System Integrity:\u003c\/b\u003e Significantly reduces the risk of splashing or environmental contamination from gastric fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUniversal Adapter:\u003c\/b\u003e Designed for compatibility with standard enteral feeding sets, suction tubing, and NG tubes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIntegrated Medication Port:\u003c\/b\u003e Provides a dedicated access point for syringes, eliminating the need for constant line manipulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eLatex-Free Construction:\u003c\/b\u003e Manufactured without natural rubber latex to ensure patient and clinician safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIdeal Clinical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eInstitutional Enteral Nutrition:\u003c\/b\u003e Optimized for the administration of continuous or bolus feedings for non-ambulatory patients within institutional care suites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eGastric Decompression and Suction:\u003c\/b\u003e Specifically indicated for patients requiring intermittent or continuous gastric suctioning while maintaining an irrigation port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMedication Administration Protocols:\u003c\/b\u003e Provides a secure, dedicated port for the delivery of liquid or crushed medications without breaking the primary suction\/feeding line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eClinical Gastric Sampling:\u003c\/b\u003e Used in acute care settings to facilitate the clean collection of gastric aspirate for pH testing or diagnostic analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eIn-Line Irrigation and Flushing:\u003c\/b\u003e The three-way feature allows for safer, more efficient clinical flushing of the nasogastric tube to prevent clogging and maintain patency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Details \u003c\/h3\u003e\n\u003cp\u003eBrand: LOPEZ® (Bard® \/ BD®)\u003c\/p\u003e\n\u003cp\u003eProduct Type: Closed Enteral Three-Way Valve\u003c\/p\u003e\n\u003cp\u003eMaterial: Polycarbonate (Body), Polyethylene (Core\/Cap)\u003c\/p\u003e\n\u003cp\u003eSize: Adult\u003c\/p\u003e\n\u003cp\u003eLatex Status: Not made with natural rubber latex.\u003c\/p\u003e\n\u003cp\u003eSingle Use\u003c\/p\u003e\n\u003cp\u003eNon-Sterile\u003c\/p\u003e\n\u003ch3\u003ePackaging\u003c\/h3\u003e\n\u003cp\u003eLOPEZ® Enteral Valve for Nasogastric Tube, Adult, 50\/cs\u003c\/p\u003e\n\u003ch3\u003eImportant Safety Information\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eTo view the most current and up-to-date manufacturer's information, please click \u003ca href=\"https:\/\/www.bd.com\/en-us\/products-and-solutions\/products\/product-page.0056000#eifusandresources\" title=\"Tubes, Nasogastric (NG), LOPEZ® Valve (Enteral Valve)\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eContraindications\u003c\/p\u003e\n\u003cp\u003eDo not use this device for the administration of intravenous (\u003cb data-path-to-node=\"11\" data-index-in-node=\"62\"\u003eIV\u003c\/b\u003e) fluids or medications, as this can lead to catastrophic medical errors and significant patient injury.\u003c\/p\u003e\n\u003cp\u003eDo not use this valve on pediatric or neonatal tubing sets if the tapered connectors do not provide a verified, secure fit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarnings \u0026amp;\u003c\/strong\u003e \u003cstrong\u003ePrecautions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure the stopcock lever is fully clicked into the desired position before initiating feeding or suction. An unseated valve is a high-risk leakage and exposure hazard.\u003c\/p\u003e\n\u003cp\u003eEnsure that the medicinal port cap is securely tethered and closed when not actively being used for administration to prevent the backflow of gastric contents.\u003c\/p\u003e\n\u003cp\u003eAlways ensure the valve is flushed according to facility protocol after medication delivery to prevent the buildup of residue that could seize the internal stopcock mechanism.\u003c\/p\u003e\n\u003cp\u003eMonitor the valve for cracks, leaks, or stiffness in the lever. If the polycarbonate housing shows signs of crazing or the valve becomes difficult to turn, the unit must be replaced immediately to maintain the safety integrity of the enteral circuit.\u003c\/p\u003e\n\u003cp\u003eClean the external surfaces of the valve regularly with non-abrasive institutional-grade disinfectants. Avoid using harsh chemical solutions that may degrade the integrity of the plastic housing over time.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWARNING: This product can expose you to di(2-ethylhexyl) phthalate (DEHP), which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to: https:\/\/www.P65Warnings.ca.gov.\u003c\/span\u003e\u003c\/p\u003e","brand":"BD","offers":[{"title":"Default Title","offer_id":42647795794016,"sku":"0056000","price":260.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/3375\/3696\/files\/7798f8d1609ab9bb8049a932360ef527.jpg?v=1773613047","url":"https:\/\/www.totalmobilitysolutions.com\/products\/bard-lopez%c2%ae-enteral-valve-for-nasogastric-tube-adult-50-cs","provider":"Total Mobility Solutions","version":"1.0","type":"link"}