{"product_id":"bionix-declogger®-for-enteral-feeding-tubes-16-22-fr-10-bx","title":"912 - Bionix Declogger® for Enteral Feeding Tubes - 16-22 FR, 10\/bx","description":"\u003ch3\u003eDeclogger® for Enteral Feeding Tubes - 16-22 FR, 10\/bx\u003c\/h3\u003e\n\u003cp\u003ePlease note: All prices are for boxes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe DeClogger® (Bionix, LLC) (912) is a specialized, flexible medical device designed to restore the patency of obstructed gastrostomy (G) and jejunostomy (J) tubes. Engineered with a proprietary threaded design, the DeClogger® (912) allows healthcare professionals to bore through tough occlusions—such as formula buildup or medication clogs—without the need for tube replacement. The tool features a flexible polypropylene shaft that conforms to the curvature of the feeding tube, minimizing the risk of internal damage or puncture.\u003c\/p\u003e\n\u003cp data-path-to-node=\"3\"\u003eSafety is integrated into the design via a built-in Stop Disc, which prevents over-insertion and ensures the device does not enter the patient's gastrointestinal tract. The yellow-coded DeClogger® (912) is sized for standard gastrostomy or jejunostomy tubes with a length of 39.5 cm. Routine use of the DeClogger® (912) serves as a maintenance tool to avoid the formation of dense clogs, thereby reducing clinical interruptions and ensuring the consistent delivery of nutrients and medications.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,0,0\"\u003eMechanical Deobstruction Versatility:\u003c\/b\u003e Functions seamlessly as a specialized tool for clearing localized clogs within a designated clinical space.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,2,0\"\u003eThreaded \"Screw-Tip\" Design:\u003c\/b\u003e Facilitates easy, mechanical engagement with formula clogs to break them apart for subsequent flushing.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,3,0\"\u003eIntegrated Depth Markers:\u003c\/b\u003e Provides a stable, visual reference for the clinician to track the insertion depth and avoid over-advancement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,4,0\"\u003eStandard Luer Connection:\u003c\/b\u003e Outfitted with a safety disc to prevent over-insertion and provide a secure grip during the rotation and extraction process.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,1,0\"\u003eReinforced Flexible Stem:\u003c\/b\u003e Provides the structural integrity required to navigate tube bends while maintaining enough rigidity to apply pressure to the obstruction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eIdeal Clinical Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eInstitutional Enteral Maintenance:\u003c\/b\u003e Optimized for the restoration of flow in large-bore feeding tubes for non-ambulatory patients within institutional care suites.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003ePost-Medication Flush Protocols:\u003c\/b\u003e Specifically indicated for clearing tubes that have become occluded by improperly crushed medications or thick formula residues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eEmergency Tube Salvage:\u003c\/b\u003e Provides a secure, immediate alternative to surgical or radiological tube replacement for patients with critical nutritional needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eRehabilitation Support:\u003c\/b\u003e Used in clinical settings to maintain the patency of long-term enteral access sites during a patient’s stay in a facility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eTube Patency Management:\u003c\/b\u003e The mechanical design allows for safer, more efficient clinical clearing of stubborn clogs that chemical decloggers cannot penetrate.\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Details\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eBrand: Declogger® (Bionix)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProduct Type: Enteral Feeding Tube Declogger\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMaterial: Medical-grade Polypropylene\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLength: 39.5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSize: 16-22 FR\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eColor: Yellow\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLatex Status: Not made with natural rubber latex.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSingle Use\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNon-Sterile\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePackaging\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eDeclogger® for Enteral Feeding Tubes - 16-22 FR, 10\/bx\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eImportant Safety Information\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's product \u0026amp; safety information can be found \u003ca rel=\"noopener\" title=\"bionix DECLOGGER® FOR ENTERAL FEEDING TUBES 14-16 FR, blue, 10\/bx\" href=\"https:\/\/bionix.com\/products\/declogger\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContraindications\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eDo not use this device in tubes smaller than \u003cb data-path-to-node=\"11\" data-index-in-node=\"45\"\u003e16 FR\u003c\/b\u003e, as this can lead to tube rupture, entrapment of the tool, and significant patient injury.\u003c\/p\u003e\n\u003cp\u003eDo not use this tool if the feeding tube is known or suspected to be malpositioned or if the integrity of the tube wall is compromised.\u003c\/p\u003e\n\u003cp\u003eDo not use this device on nasogastric (NG) or nasojejunal (NJ) tubes. The DeClogger® (912) is sized for G and J tubes and is not appropriate for the length or diameter requirements of nasal access lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarnings \u0026amp; Precautions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003eThis device is for professional use only and should only be operated by a licensed healthcare provider. Incorrect use by untrained individuals can result in tube damage or patient injury.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003eThis is a single-use device. Reusing the DeClogger® (912) can compromise the mechanical integrity of the plastic threads and introduces a significant risk of cross-contamination and healthcare-associated infections (HAIs).\u003c\/p\u003e\n\u003cp data-path-to-node=\"18\"\u003eCheck the feeding tube size and type before use. Using the DeClogger® (912) in a tube smaller than 16 FR can cause the device to become stuck, while using it in a tube larger than 22 FR may result in ineffective clearing.\u003c\/p\u003e\n\u003cp data-path-to-node=\"19\"\u003eAlways inspect the device for kinks or stress marks before insertion. If the polypropylene shaft is bent or weakened, discard the unit to prevent it from snapping inside the enteral tube.\u003c\/p\u003e\n\u003cp data-path-to-node=\"20\"\u003eNote that the DeClogger® (912) is incompatible with ENFit® connectors; verify connection types before attempting use.\u003c\/p\u003e\n\u003cp\u003e\u003cb data-path-to-node=\"22\" data-index-in-node=\"0\"\u003e⚠ WARNING:\u003c\/b\u003e This product can expose you to chemicals including \u003cb data-path-to-node=\"22\" data-index-in-node=\"62\"\u003eDi(2-ethylhexyl)phthalate (DEHP)\u003c\/b\u003e and \u003cb data-path-to-node=\"22\" data-index-in-node=\"99\"\u003eDiisononyl phthalate (DINP)\u003c\/b\u003e, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003ca rel=\"noopener\" href=\"http:\/\/www.P65Warnings.ca.gov\" class=\"ng-star-inserted\" target=\"_blank\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e.\u003c\/p\u003e","brand":"Bionix","offers":[{"title":"Default Title","offer_id":42647769088096,"sku":"912","price":89.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/3375\/3696\/files\/BNX_912.jpg?v=1773609010","url":"https:\/\/www.totalmobilitysolutions.com\/products\/bionix-declogger%c2%ae-for-enteral-feeding-tubes-16-22-fr-10-bx","provider":"Total Mobility Solutions","version":"1.0","type":"link"}