{"product_id":"bionix-declogger®-for-enteral-feeding-tubes-18-24-fr-10-bx-copy","title":"913 - Bionix Declogger® for Enteral Feeding Tubes - 20-22 FR, 10\/bx","description":"\u003ch3\u003eDeclogger® for Enteral Feeding Tubes - 20-22 FR, 10\/bx\u003c\/h3\u003e\n\u003cp\u003ePlease note: All prices are for boxes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe Bionix DeClogger® (913) is a specialized, flexible medical device designed to restore the patency of obstructed gastrostomy (G), jejunostomy (J), and percutaneous endoscopic gastrostomy (PEG) tubes. Engineered with a proprietary threaded design, the DeClogger® (913) allows healthcare professionals to bore through tough occlusions—such as formula buildup or medication clogs—without the need for tube replacement. The tool features a flexible polypropylene shaft that conforms to the curvature of the feeding tube, minimizing the risk of internal damage or puncture.\u003c\/p\u003e\n\u003cp data-path-to-node=\"3\"\u003eSafety is integrated into the design via a built-in Stop Disc, which prevents over-insertion and ensures the device does not enter the patient's gastrointestinal tract. The blue-coded DeClogger® (913) is sized for PEG-style or replacement tubes that are shorter in length. Routine use of the DeClogger® (913) serves as a maintenance tool to avoid the formation of dense clogs, thereby reducing clinical interruptions and ensuring the consistent delivery of nutrients and medications.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eMechanical Deobstruction Versatility:\u003c\/b\u003e Functions seamlessly as a specialized tool for clearing localized clogs within a designated clinical space.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eThreaded \"Screw-Tip\" Design:\u003c\/b\u003e Facilitates easy, mechanical engagement with formula clogs to break them apart for subsequent flushing.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eIntegrated Depth Markers:\u003c\/b\u003e Provides a stable, visual reference for the clinician to track the insertion depth and avoid over-advancement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eStandard Luer Connection:\u003c\/b\u003e Outfitted with a safety disc to prevent over-insertion and provide a secure grip during the rotation and extraction process.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eReinforced Flexible Stem:\u003c\/b\u003e Provides the structural integrity required to navigate tube bends while maintaining enough rigidity to apply pressure to the obstruction.\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eIdeal Clinical Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eLarge-Bore PEG and Replacement Tube Clearing:\u003c\/b\u003e Sized for the shorter lengths and wider diameters typical of 20-22 FR PEG and replacement-style enteral tubes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eMedication Occlusion Removal:\u003c\/b\u003e Clears tubes blocked by undissolved pill fragments or thick medication suspensions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003ePreventive Maintenance:\u003c\/b\u003e Used during routine tube care to ensure long-term patency and prevent biofilm accumulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Details\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eBrand: DeClogger® (Bionix®)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProduct Type: Enteral Feeding Tube Declogger\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMaterial: Medical-grade Polypropylene\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLength: 39.5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSize: 20-22 FR\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eColor: Green\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLatex Status: Not made with natural rubber latex.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSingle Use\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNon-Sterile\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePackaging\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eDeclogger® for Enteral Feeding Tubes - 20-22 FR, 10\/bx\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eImportant Safety Information\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's product \u0026amp; safety information can be found \u003ca href=\"https:\/\/bionix.com\/products\/declogger\" title=\"bionix DECLOGGER® FOR ENTERAL FEEDING TUBES 14-16 FR, blue, 10\/bx\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContraindications\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eDo not use this device in tubes smaller than \u003cb data-path-to-node=\"11\" data-index-in-node=\"45\"\u003e20 FR\u003c\/b\u003e, as this can lead to tube rupture, entrapment of the tool, and significant patient injury.\u003c\/p\u003e\n\u003cp\u003eDo not use this tool if the feeding tube is known or suspected to be malpositioned or if the integrity of the tube wall is compromised.\u003c\/p\u003e\n\u003cp\u003eDo not use this device on nasogastric (NG) or nasojejunal (NJ) tubes. The DeClogger® (922) is sized for G, J, and PEG tubes and is not appropriate for the length or diameter requirements of nasal access lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarnings \u0026amp; Precautions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure the \u003cb data-path-to-node=\"14\" data-index-in-node=\"11\"\u003eBionix Declogger®\u003c\/b\u003e is inserted with gentle pressure. Forcing the tool against a solid resistance is a high-risk perforation hazard.\u003c\/p\u003e\n\u003cp\u003eAlways ensure the tube is flushed with water after using the tool to remove any loosened debris that could cause a secondary obstruction.\u003c\/p\u003e\n\u003cp\u003eMonitor the tool for signs of kinking or stress fractures during use. If the plastic stem shows signs of whitening or fatigue, the unit must be replaced immediately to prevent the tool from breaking off inside the feeding tube.\u003c\/p\u003e\n\u003cp\u003eThis device is designed for single-patient, single-use only. Reusing the tool can lead to cross-contamination between patients and a loss of mechanical integrity, increasing the risk of device failure.\u003c\/p\u003e\n\u003cp\u003e\u003cb data-path-to-node=\"22\" data-index-in-node=\"0\"\u003e⚠ WARNING:\u003c\/b\u003e This product can expose you to chemicals including \u003cb data-path-to-node=\"22\" data-index-in-node=\"62\"\u003eDi(2-ethylhexyl)phthalate (DEHP)\u003c\/b\u003e and \u003cb data-path-to-node=\"22\" data-index-in-node=\"99\"\u003eDiisononyl phthalate (DINP)\u003c\/b\u003e, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003ca rel=\"noopener\" href=\"http:\/\/www.P65Warnings.ca.gov\" class=\"ng-star-inserted\" target=\"_blank\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e.\u003c\/p\u003e","brand":"Bionix","offers":[{"title":"Default Title","offer_id":42647791698016,"sku":"913","price":96.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/3375\/3696\/files\/BNX_913.jpg?v=1773612458","url":"https:\/\/www.totalmobilitysolutions.com\/products\/bionix-declogger%c2%ae-for-enteral-feeding-tubes-18-24-fr-10-bx-copy","provider":"Total Mobility Solutions","version":"1.0","type":"link"}