{"product_id":"molnlycke-avance-negative-pressure-wound-products-avance-solo-closed-incision-starter-kit-10cm-x-20cm-1-bx-2-bx-cs","title":"8881020 - Mölnlycke® Avance® Negative Pressure Wound Products - Avance Solo Closed Incision Starter Kit, 10cm x 20cm, 1\/bx, 2 bx\/cs","description":"\u003ch3\u003eAvance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Negative Pressure Wound Products - Avance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo Closed Incision Starter Kit, 10cm x 20cm, 1\/bx, 2 bx\/cs\u003c\/h3\u003e\n\u003cp\u003ePlease note: All prices are for cases.\u003c\/p\u003e\n\u003cp\u003eThe Mölnlycke® Avance® Solo Closed Incision Starter Kit (SKU 8881020) is a sterile, single-patient use negative pressure wound therapy (NPWT) system designed specifically for the management of closed surgical incisions (ciNPT) and low-to-moderate exuding wounds. The system utilizes Controlled Fluid Management (CFM) Technology™ to deliver a continuous, regulated negative pressure of -125 mmHg for up to 14 days. By combining an absorbent multilayer dressing with a 50 mL distal canister, the system effectively manages exudate through both absorption and moisture vapor evaporation while transporting excess fluid away from the wound bed to prevent saturation.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eControlled Fluid Management (CFM) Technology™:\u003c\/b\u003e A proprietary airflow system that ensures the pump delivers a consistent -125 mmHg vacuum even in the presence of wound fluid, reducing the risk of therapy loss.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003e14-Day Continuous Therapy:\u003c\/b\u003e The single-button pump is programmed to operate for up to 14 days, accommodating extended post-operative recovery periods.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eSafetac® Technology Wound Contact Layer:\u003c\/b\u003e The soft silicone adhesive layer allows for easy repositioning during application and is clinically proven to reduce skin stripping and pain upon removal.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eDual Exudate Management:\u003c\/b\u003e Features a breathable film backing that allows for high moisture vapor transmission while the 50 mL canister collects excess liquid to prevent dressing saturation and maceration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eVisual and Audible Alarms:\u003c\/b\u003e Integrated sensors provide notifications for \"Leakage,\" \"Blockage,\" and \"Low Battery,\" ensuring the user is alerted to any interruption in therapy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eErgonomic Portability:\u003c\/b\u003e The compact, pocket-sized pump and distal canister design allow patients to remain ambulatory and maintain daily activities during treatment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eIdeal Clinical Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eClosed Surgical Incisions (ciNPT):\u003c\/b\u003e Indicated for high-risk surgical sites following orthopaedic (hip\/knee arthroplasty), cardiothoracic (sternotomy), and OB-GYN (C-section) procedures to reduce surgical site complications.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eVascular and General Surgery:\u003c\/b\u003e Management of groin incisions, laparotomies, and ventral hernia repairs where stabilizing incision edges is critical.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eChronic and Acute Wounds:\u003c\/b\u003e Suitable for managing low-to-moderate exuding diabetic foot ulcers, pressure injuries, and traumatic wounds.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eGrafts and Flaps:\u003c\/b\u003e Provides stabilization and fluid removal to support the successful integration of skin grafts and surgical tissue flaps.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eProduct Details\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBrand: \u003cspan class=\"\"\u003eAvance® Mölnlycke® Health Care\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eProduct Type: Negative Pressure Wound Therapy (NPWT) Replacement Canister\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCompatible With: Mölnlycke\u003cspan class=\"\"\u003e®\u003c\/span\u003e Avance® Solo Portable NPWT System\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eLatex Status: Not Made with Natural Rubber Latex\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSingle-Use \/ Reusable: Single-Use (Disposable)\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePackaging\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eAvance\u003cspan\u003e\u003cspan class=\"\"\u003e®\u003c\/span\u003e\u003c\/span\u003e Negative Pressure Wound Products - Avance\u003cspan\u003e\u003cspan class=\"\"\u003e®\u003c\/span\u003e\u003c\/span\u003e Solo Closed Incision Starter Kit, 10cm x 20cm, 1\/bx, 2 bx\/cs\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eManufacturer Precautions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eTo view a complete list of the most current and up-to-date manufacturer's safety information, please click \u003ca href=\"https:\/\/www.molnlycke.com\/en-us\/products\/wound-care\/negative-pressure-wound-therapy\/avance-solo?variantId=8881020\" title=\"MOLNLYCKE AVANCE NEGATIVE PRESSURE WOUND PRODUCTS Avance Solo Dressing, 10cm x 20cm, 2\/bx, 2 bx\/cs\" rel=\"noopener\" target=\"_blank\"\u003ehere.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eImportant Safety Information\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eBefore starting therapy, evaluate the patient’s nutritional status and address severe malnutrition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSigns of possible infection or complications must be addressed immediately. Monitor the device, wound, surrounding skin, and patient status accordingly to ensure effective and safe treatment and patient comfort.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor patients with ischemic condition or at application of a circumferential dressing, extra monitoring of wound status is required to avoid risk of compromised circulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo Pump is equipped with visual and audible notifications and alarms. Ensure that carrying or placement of the pump allows the user to detect audible and visual notifications and alarms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen the Avance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo Pump battery low alarm is triggered, replace the batteries in the pump. Only use the type and model of lithium batteries specified for this product by Mölnlycke\u003cspan class=\"\"\u003e®\u003c\/span\u003e Health Care.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFixation strips provided with the dressing must only be applied on dressing borders. Do not apply fixative strips, or other occlusive dressings, across the dressing wound pad, due to the risk of low breathability leading to maceration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eApplication of certain skin protection products or using cleansing products prior to the application of the dressing may affect the ability of the dressing and fixative strips to adhere securely and create sufficient sealing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDo not use the products on patients and\/or users with known hypersensitivity to the products' ingoing materials\/components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIngrowth of tissue may occur if the dressing or wound filler is not changed according to recommendations or as appropriate for the individual patient's wound condition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConsider use of a non-adherent wound contact layer (Mepitel) to protect fragile tissue.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDo not place the pump with canister in water or other liquids. Disconnect the pump and canister if the ingress of water is observed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor daily hygiene routines, do not expose the pump with canister or dressing to extensive contact with water.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo Border Dressing should only be applied and changed by healthcare professionals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNo modification of this device (pump, canister, tubes, dressing) is allowed as modifications may significantly compromise the system's ability to deliver therapy. Products in the Avance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo NPWT System should not be used with products from other NPWT systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDo not cut the tube or detach it from the canister. Do not cut the dressing. Do not disassemble the pump. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo Pump is not intended for use aboard aircraft. Remove the batteries during air travel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo NPWT System products are provided sterile. Do not use if the sterile barrier is damaged or has been opened prior to use. Do not resterilize.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDo not reuse Avance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo NPWT System products. If reused, the product's performance may deteriorate, and cross contamination may occur.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor CT scans and x-ray investigations, keep the pump out of the x-ray or scanner range. In the event that the pump is within a CT-scan or x-ray range, be sure to check that the pump functions correctly after the procedure. The potential for electromagnetic interference in all environments cannot be eliminated. Use caution if the pump is near electronic equipment such as anti-theft equipment or metal detectors and ensure proper function.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarnings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eApplication of NPWT may increase the risk of bleeding. If sudden or increased bleeding is observed, immediately take appropriate action to stop bleeding and seek emergency medical attention.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePatients at high risk of bleeding, such as those receiving anticoagulant therapy or with altered hemostasis, must be monitored closely during therapy. Be sure to establish hemostasis before applying therapy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePatients at risk of bleeding complications due to a history of vascular anastomosis or friable, irradiated, sutured or infected blood vessels, for example, should be monitored carefully during therapy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePatients undergoing NPWT need frequent supervision. Routinely check that the negative pressure therapy is active, the dressing should be contracted and firm to the touch. If it is necessary to discontinue therapy, the time elapsed without negative pressure must comply with instructions from a healthcare professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBe sure that the pump, dressing and canister tubes, quick connectors and transfer port are positioned to eliminate the risk of - imprints - contamination - entrapment or strangulation - kinking or blocking of tubes - exposure to heat sources.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCover or remove sharp edges or bones in the wound prior to the application of the dressing due to the risk of puncturing organs and blood vessels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf defibrillation is required, disconnect the pump and remove the dressing if its positioning interferes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo Pump is magnetic resonance (MR) unsafe, do not take into a magnetic resonance imaging (MRI) environment. Avance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo Border Dressings and Avance Solo Foam are MR safe. The impact of the dressing and foam on magnetic resonance tomography (MRT)\/magnetic resonance imaging (MRI) artifacts is unknown.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo Pump must not be used in oxygen rich environments where there is a danger of explosion, e.g., a hyperbaric oxygen unit or in therapy\/investigations involving microwaves. For the dressing, static electricity may be created when removing the release liner from the strips, so Consider if the dressing needs to be removed for safety reasons.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvance\u003cspan class=\"\"\u003e®\u003c\/span\u003e Solo Pump is not suitable for use in the presence of flammable anesthetics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSpinal Cord Injury: If the patient experiences autonomic dysreflexia (sudden elevation in blood pressure or heart rate in response to stimulation of the sympathetic nervous system), immediately stop the therapy to help minimize sensory stimulation and seek emergency medical attention.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePlease refer to the manufacturer's website for a complete list of warnings (linked above).\u003c\/span\u003e\u003c\/p\u003e","brand":"Mölnlycke","offers":[{"title":"Default Title","offer_id":42649333137504,"sku":"8881020","price":1602.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/3375\/3696\/files\/MOL_8881020.jpg?v=1773713408","url":"https:\/\/www.totalmobilitysolutions.com\/products\/molnlycke-avance-negative-pressure-wound-products-avance-solo-closed-incision-starter-kit-10cm-x-20cm-1-bx-2-bx-cs","provider":"Total Mobility Solutions","version":"1.0","type":"link"}